Search results for "Voltage source inverter"
showing 9 items of 9 documents
Current fault signatures of Voltage Source Inverters in different reference frames
2016
This paper considers different current patterns used to identify the correct fault signatures in Voltage Source Inverters (VSI). At the beginning, the Authors consider the currents patterns from which a simple or a double fault can be encompassed both in the case of controllable device only or with its free wheeling companion diode. After the discussion of diagnosis algorithm suitable for electrical drives and principally based on a persistent near zero current condition current in the natural phase reference frame, the stationary reference frame is then considered as a tool to identify both the faulted phase as the device or various combination of faulted devices. On the contrary, the Auth…
An Adaptive Robust Predictive Current Control for Three-Phase Grid-Connected Inverters
2011
This paper presents an adaptive robust predictive current control (RPCC) for grid-connected three-phase inverters that exhibit zero steady-state current error. The error correction is achieved by means of an adaptive strategy that works in parallel with the deadbeat algorithm, therefore preserving the typical fast response of the predictive law. The resulting control adapts to any particular L or LCL filter by estimation of the resistive part of the filter. As a variety of the RPCC class of control, it offers the best tradeoff between robustness and speed. © 2009 IEEE.
Decoupled control scheme of the grid-connected split-source inverter for renewable energy sources
2016
Grid-connected power conversion systems for renewable energy sources must fulfill several requirements, including high efficiency, reduced cost and complexity, and, quite often, also boost capabilities from the dc sources to the ac power grid. For such applications, single-stage power converters with boost capabilities offer some potential advantages. Among several proposed options, split-source inverter (SSI) has been recently investigated. This paper proposes a decoupled control scheme for the SSIs, where the common mode term of the ac modulation signals is used to control the dc input current. Thus, the dc input current and ac output current can be controlled independently. The proposed …
Mathematical modelling of an inverter-based distributed generator
2016
In this paper, a modeling approach of a three phase power inverter based on an electrostatic synchronous machine is presented. By the proposed approach, any inverter-based distributed generator in a microgrid can be replaced by an equivalent electrostatic machine. This paper aims to promote the use of the proposed modeling approach in the analysis of microgrid stability. Thanks to the proposed modeling approach, transient performances of on-grid operation of converter-based distributed generators could be easily analyzed by multi-machine models. Parameters of the equivalent synchronous electrostatic machine model are derived to achieve equivalence with the inverter model. Small signal model…
A review of multiple faults diagnosis methods in Voltage Source Inverters
2015
This paper examines, as in short review, the methods of diagnosis of simple and multiple faults on Voltage Source Inverter (VSI). The methods examined here are essentially based on the inspection of the load currents. Some of these diagnosis methods are characterized by low computational effort, other for a better reliability avoiding faultless positive tests. Some solutions are characterized by a share of these benefits while others prefer an enforcement of trustworthiness, in spite of the lower calculation amount. The analysis of the technical literature, certainly, offers a glimpse about the creation of new algorithms and significant advances for the future.
Grid synchronization of DC energy storage using Voltage Source Inverter with ZCD and PLL techniques
2015
To increase the penetration of renewable energy sources, a proper energy storage is required. In this context, there is a growing concern about the use of energy storage for overcoming the intermittency of renewable energy sources as well as in demand side management. In order to accomplish grid synchronization of energy storage, proper power conditioning devices are required. This paper analyses single phase grid synchronization of DC energy storage using MATLAB Simulink ® environment. The considered power conditioning device is a Voltage Source Inverter (VSI), which is controlled using two methods called (i) traditional Zero Crossing Detection (ZCD) technique and (ii) the phase detector b…
Decoupled Control Scheme of Grid-Connected Split-Source Inverters
2017
During the last few years, single-stage power conversion systems has undergone a fast evolution to replace the conventional two-stage architecture, which includes a front-end dc-dc boost converter (BC) and an output voltage source inverter (VSI) [1]. This evolution has grown up to improve the overall system performance in terms of reducing its size, weight, and complexity. Most of these single-stage topologies and their different modulation schemes have been reviewed in [1]. Among these different single-stage options, the split-source inverter (SSI), shown in Figure 1, has been recently proposed in [2] as a single-stage dc-ac power converter topology to overcome some demerits in the other s…
INVERTER-BASED DISTRIBUTED GENERATORS, MODELING AND CONTROL
In the last few years, electrical power generation is moving from a centralized generation towards distributed generation including on-site Renewable Energy Sources (RESs). In order to overcome RES related issues, as intermittent and fluctuating power, storage elements are included in the on-site generation system. The interaction between distributed generator (DG) units including RES, storage and front-end power converters should be carefully modeled in order to analyze the power system stability. An accurate modeling of DGs is required. In this thesis, a new modeling approach has been proposed for the inverter-based DGs based on the concept of electrostatic synchronous machines. Detailed …
Decoupled control scheme of grid-connected split-source inverters
2017
Grid-connected power conversion systems for renewable energy sources must fulfill several requirements, e.g., the high efficiency, the reduced cost and complexity, and, quite often, the boost capabilities that is usually achieved using a front-end dc–dc boost converter before the inversion stage, leading to a two-stage architecture. Meanwhile, single-stage power conversion systems, which perform the boosting operation within the inversion one, offer some potential advantages, in terms of reducing the complexity and the volume of the whole system. Among several proposed options, the split-source inverter (SSI) has been recently proposed by Abdelhakim et al. as an alternative option with some…